Infinium - OMNI III High Acuity Patient Monitor
High Acuity Monitoring
The Infinium OMNI III High Acuity Patient Monitor is designed for continuous monitoring in critical care and fast-paced clinical environments. The system integrates a 15-inch high-resolution touchscreen display with an adaptable user interface that allows clinicians to access patient information and configure vital sign parameters directly from the main screen.
The monitor supports rapid adjustment of patient data fields, alarm parameters, and vital sign configurations to accommodate changing patient conditions. Its interface architecture allows efficient navigation between monitoring functions while maintaining clear visualization of physiological data required in high-acuity care settings.
Engineered for hospital use, the OMNI III provides compatibility with multi-parameter monitoring configurations and centralized clinical workflows. The touchscreen system enables quick configuration of monitoring parameters, supporting accurate observation of patient status in intensive care units, emergency departments, and other high-dependency clinical environments.
Features
-
Advanced Touchscreen Monitoring
The Infinium Omni III features a 15-inch high-resolution touchscreen with an intuitive, customizable interface for quick adjustments. It supports flexible screen configurations and stores up to 72 hours of patient data for efficient critical care monitoring. -
Vital Sign Monitoring Capabilities
The Omni III provides comprehensive monitoring, including NIBP/optional IBP, ECG with arrhythmia detection, SpO₂, temperature, pulse, and respiration. Optional modules add EtCO₂, anesthesia, cardiac output, and BIS monitoring, making it suitable for basic, bedside, or operating room use across multiple care settings. -
Field-Upgradeable Monitoring System
The Infinium Omni series features a modular, field-upgradable design with standard monitoring (NIBP, ECG, SpO₂, temperature, respiration) and optional plug-in modules for advanced parameters such as EtCO₂, anesthesia, cardiac output, and IBP, allowing flexible adaptation to changing patient needs. -
HL7 Connectivity & Central Monitoring
The Omni III supports HL7-compliant network integration via Ethernet and RS-232 for seamless data transfer to hospital systems. It also connects to the Infinium Omniview Central Station, enabling real-time monitoring of up to 32 devices with data storage, printing, and trend review.
Specifications
| Performance Specifications | |
|---|---|
| Application | Adult, Pediatric, Neonatal |
| Display | 15" color touch screen |
| Waveform Display | 3, 6, 8, 10, or 12 waveforms |
| Indicators | Alarm and power indicators with QRS beep and alarm sound |
| Trend Storage | 120 hours |
| Recorder | Built-in thermal array, 3 channels, 48 mm paper width, 50 mm/sec speed |
| Networking | RJ45 port, HL7 compatible |
| AC Power | 100–240 VAC, 50/60 Hz, 150 VA |
| Battery | Rechargeable lithium-ion |
| Environmental | |
| Temperature | Operating 0–40°C, Storage -20–60°C |
| Humidity | Operating 15–95%, Storage 10–95% (non-condensing) |
| Standard Features | |
| Parameters | ECG (cascading), Respiration, NIBP (up to 250 readings), Temperature, Masimo SpO2, Pulse, Perfusion Index |
| System Features | OxyCRG, Drug dose calculation, user settings memory, arrhythmia detection, ST segment analysis |
| ECG | |
| Input | 3, 5, or 12-lead ECG cable, AAMI standard |
| Lead Selection | I, II, III, aVR, aVL, aVF, V1–V6, Test |
| Gain Options | ×0.5, ×1, ×2, ×4 |
| Frequency Response | 0.05–35 Hz |
| Heart Rate Range | 30–300 bpm |
| Accuracy | ±1 bpm or ±1% |
| Respiration | |
| Method | RA-LL impedance |
| Range | 0–120 rpm |
| Accuracy | ±3 rpm |
| NIBP | |
| Method | Automatic oscillometric measurement |
| Modes | Manual, Auto, STAT, Average |
| Pulse Range | 30–300 bpm |
| Resolution | 1 mmHg |
| Temperature | |
| Range | 25–50°C |
| Resolution | 0.1°C |
| Channels | 2 channels |
| Masimo SET SpO2 | |
| Range | 1–100% |
| Resolution | 1% |
| IBP (Optional) | |
| Range | -10–300 mmHg |
| Channels | 2 channels |
| EtCO2 (Optional) | |
| CO2 Range | 0–150 mmHg |
| Sampling Rate | 50 ml/min |
Original: $3,371.00
-65%$3,371.00
$1,179.85Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
High Acuity Monitoring
The Infinium OMNI III High Acuity Patient Monitor is designed for continuous monitoring in critical care and fast-paced clinical environments. The system integrates a 15-inch high-resolution touchscreen display with an adaptable user interface that allows clinicians to access patient information and configure vital sign parameters directly from the main screen.
The monitor supports rapid adjustment of patient data fields, alarm parameters, and vital sign configurations to accommodate changing patient conditions. Its interface architecture allows efficient navigation between monitoring functions while maintaining clear visualization of physiological data required in high-acuity care settings.
Engineered for hospital use, the OMNI III provides compatibility with multi-parameter monitoring configurations and centralized clinical workflows. The touchscreen system enables quick configuration of monitoring parameters, supporting accurate observation of patient status in intensive care units, emergency departments, and other high-dependency clinical environments.
Features
-
Advanced Touchscreen Monitoring
The Infinium Omni III features a 15-inch high-resolution touchscreen with an intuitive, customizable interface for quick adjustments. It supports flexible screen configurations and stores up to 72 hours of patient data for efficient critical care monitoring. -
Vital Sign Monitoring Capabilities
The Omni III provides comprehensive monitoring, including NIBP/optional IBP, ECG with arrhythmia detection, SpO₂, temperature, pulse, and respiration. Optional modules add EtCO₂, anesthesia, cardiac output, and BIS monitoring, making it suitable for basic, bedside, or operating room use across multiple care settings. -
Field-Upgradeable Monitoring System
The Infinium Omni series features a modular, field-upgradable design with standard monitoring (NIBP, ECG, SpO₂, temperature, respiration) and optional plug-in modules for advanced parameters such as EtCO₂, anesthesia, cardiac output, and IBP, allowing flexible adaptation to changing patient needs. -
HL7 Connectivity & Central Monitoring
The Omni III supports HL7-compliant network integration via Ethernet and RS-232 for seamless data transfer to hospital systems. It also connects to the Infinium Omniview Central Station, enabling real-time monitoring of up to 32 devices with data storage, printing, and trend review.
Specifications
| Performance Specifications | |
|---|---|
| Application | Adult, Pediatric, Neonatal |
| Display | 15" color touch screen |
| Waveform Display | 3, 6, 8, 10, or 12 waveforms |
| Indicators | Alarm and power indicators with QRS beep and alarm sound |
| Trend Storage | 120 hours |
| Recorder | Built-in thermal array, 3 channels, 48 mm paper width, 50 mm/sec speed |
| Networking | RJ45 port, HL7 compatible |
| AC Power | 100–240 VAC, 50/60 Hz, 150 VA |
| Battery | Rechargeable lithium-ion |
| Environmental | |
| Temperature | Operating 0–40°C, Storage -20–60°C |
| Humidity | Operating 15–95%, Storage 10–95% (non-condensing) |
| Standard Features | |
| Parameters | ECG (cascading), Respiration, NIBP (up to 250 readings), Temperature, Masimo SpO2, Pulse, Perfusion Index |
| System Features | OxyCRG, Drug dose calculation, user settings memory, arrhythmia detection, ST segment analysis |
| ECG | |
| Input | 3, 5, or 12-lead ECG cable, AAMI standard |
| Lead Selection | I, II, III, aVR, aVL, aVF, V1–V6, Test |
| Gain Options | ×0.5, ×1, ×2, ×4 |
| Frequency Response | 0.05–35 Hz |
| Heart Rate Range | 30–300 bpm |
| Accuracy | ±1 bpm or ±1% |
| Respiration | |
| Method | RA-LL impedance |
| Range | 0–120 rpm |
| Accuracy | ±3 rpm |
| NIBP | |
| Method | Automatic oscillometric measurement |
| Modes | Manual, Auto, STAT, Average |
| Pulse Range | 30–300 bpm |
| Resolution | 1 mmHg |
| Temperature | |
| Range | 25–50°C |
| Resolution | 0.1°C |
| Channels | 2 channels |
| Masimo SET SpO2 | |
| Range | 1–100% |
| Resolution | 1% |
| IBP (Optional) | |
| Range | -10–300 mmHg |
| Channels | 2 channels |
| EtCO2 (Optional) | |
| CO2 Range | 0–150 mmHg |
| Sampling Rate | 50 ml/min |